  • 5 FEBRUARY 2026 - 5 APRIL 2026

    UNDER DEVELOPMENT

    5 FEBRUARY 2026 - 5 APRIL 2026

    No.

    Title of DMS

    Scope

    Details

     

    NSC 18 - MEDICAL DEVICE AND FACILITIES FOR HEALTHCARE

    1

    DMS IEC/TR 62354:2014

    General testing procedures for medical electrical equipment

    This Malaysian Standard provides general testing procedures for medical electrical equipment.

    This technical report applies to medical electrical equipment.

    The object of this technical report is to provide guidance on general testing procedures according to IEC 60601-1:1988 (including the collateral provisions of IEC 60601-1-1:2000) and IEC 60601-:2005 and IEC 60601-1:2005/AMD1:2012.

    DOCUMENT

    PUBLIC COMMENT FORM

    Email: pc[at]jsm[dot]gov[dot]my

  • 15 FEBRUARY 2026 - 15 APRIL 2026

    UNDER DEVELOPMENT

    15 FEBRUARY 2026 - 15 APRIL 2026

    No.

    Title of DMS

    Scope

    Details

     

    NSC 19 - ELECTRICAL AND ELECTRONICS EQUIPMENTS AND ACCESORIES 

    1

    DMS IEC 62305-1:2024

    Protection against lightning — Part 1: General principles (IEC 62305-1:2024, IDT)

    This document provides general principles for the protection of structures against lightning, including their installations and contents, as well as persons.

    The following cases are outside the scope of this document:

    – railway systems;

    – vehicles, ships, aircraft, offshore installations;

    – underground high-pressure pipelines;

    – pipe, power and telecommunication lines separated from the structure;

    – nuclear power plants.

    The IEC 62305 series should be considered as a minimum requirement for these structures.

    Until any further information by CIGRE is available the lightning current parameters described in this document can be applied also for offshore installations.

    UPC

    DOCUMENT

    PUBLIC COMMENT FORM

    Email: pc[at]jsm[dot]gov[dot]my

    2.

    DMS IEC 62305-2:2024

    Protection against lightning – Part 2: Risk management (IEC 62305-2:2024, IDT)

    Provides risk management of a structure due to lightning flashes to earth.

    Its purpose is to provide a procedure for the evaluation of such a risk. Once an upper tolerable limit for the risk has been selected, this procedure provides a means for the selection of appropriate protection measures to be adopted to reduce the risk to or below the tolerable limit.

    Risk management also includes the evaluation of frequency of damage of internal systems caused by surges due to lightning flashes to earth.

    Once an upper tolerable limit for the frequency of damage has been selected, this procedure provides a means for the selection of

    appropriate protection measures to be adopted to reduce the frequency of damage to or below the tolerable limit.

    UPC

    DOCUMENT

    PUBLIC COMMENT FORM

    Email: pc[at]jsm[dot]gov[dot]my

    3.

    DMS IEC 62305-3:2024

    Protection against lightning —Part 3: Physical damage to structures and life hazard (IEC 62305-3:2024, IDT)

    This document is applicable to the:

    a) design, installation, inspection and maintenance of an LPS for structures without limitation of their height,

    b) establishment of measures for protection against injury to human beings primarily due to touch and step voltages.

    NOTE 1 Specific requirements for an LPS in structures dangerous to their surroundings due to the risk of explosion are provided in Annex C.

    NOTE 2 This document is not intended to provide protection against failures of electrical and electronic systems due to overvoltages. Specific requirements for such cases are provided in IEC 62305-4.

    NOTE 3 Specific requirements for the protection against lightning of wind turbines are reported in IEC 61400­24.

    NOTE 4 Specific requirements for the protection against overvoltage of photovoltaic systems are reported in IEC 61643-32 and in IEC 62305-4:2024, Annex F.

    UPC

    DOCUMENT

    PUBLIC COMMENT FORM

    Email: pc[at]jsm[dot]gov[dot]my

    4.

    DMS IEC 62305-4:2024

    Protection against lightning – Part 4: Electrical and electronic systems within structures (IEC 62305-4:2024, IDT)

    This document provides requirements for the design, installation, inspection, maintenance, and testing of surge protection measures (SPM) for electrical and electronic systems to reduce the risk of permanent failures due to lightning electromagnetic impulse

    (LEMP) within a structure.

    This document does not cover protection against electromagnetic interference due to lightning, which can cause malfunctioning of internal systems.

    However, the information reported in Annex A can also be used to evaluate such disturbances. Protection measures against electromagnetic interference are covered in IEC 60364-4-44 and in the IEC 61000 series.

    This document provides guidelines for cooperation between the designer of the electrical and electronic system and the designer of the protection measures, in order to achieve optimum protection effectiveness.

    UPC

    DOCUMENT

    PUBLIC COMMENT FORM

    Email: pc[at]jsm[dot]gov[dot]my

    NSC 25 –  QUALITY AND MANAGEMENT ORGANISATION

    1.

    DMS ISO 13528:2015

    Statistical methods for use in proficiency testing by interlaboratory
    comparison (ISO 13528:2022 +
    DAmd.1:202X, IDT)

    This document provides detailed descriptions of statistical methods for proficiency testing providers to use to design proficiency testing schemes and to analyse the data obtained from those schemes. This document provides recommendations on the interpretation of proficiency testing data by participants in such proficiency testing schemes and by accreditation bodies.


    The procedures in this document can be applied to demonstrate that the measurement results obtained by laboratories, inspection bodies, and individuals meet specified criteria for acceptable performance.


    This document is applicable to proficiency testing where the results reported are either quantitative measurements or qualitative observations on test items.


    NOTE The procedures in this document can also be applied for the assessment of expert opinion where the opinions or judgments are reported in a form which can be compared
    objectively with an independent reference value or a consensus statistic. For example, when classifying proficiency test items into known categories by inspection or in determining by inspection whether proficiency test items arise, or do not arise, from the same original source and the classification results are compared objectively, the provisions of this document that relate to nominal (qualitative) properties can be applied.

    UPC

    DOCUMENT

    PUBLIC COMMENT FORM

    Email: pc[at]jsm[dot]gov[dot]my

     

  • 1 MARCH 2026 - 30 APRIL 2026

    UNDER DEVELOPMENT

    1 MARCH 2026 - 30 APRIL 2026

    No.

    Title of DMS

    Scope

    Details

     

     NSC 05 - GENERATION, TRANSMISSION AND SITRIBUTION OF ENERGY

    1.

    DMS 1979:2026

    Domestic electrical installation of buildings - Code of practice (Second revision)

    This document provides the requirements for domestic low voltage electrical installations. This document excludes domestic low voltage electrical installations of hostels, Small Office Home Office (SOHO) and Small Office Virtual Office (SOVO).

    For other than domestic low voltage electrical installations, the requirements shall refer to MS 1936 and MS IEC 60364

    UPC

    DOCUMENT

    PUBLIC COMMENT FORM

    Email: pc[at]jsm[dot]gov[dot]my

    NSC 23 - OCCUPATIONAL SAFETY AND HEALTH

    1

    DMS 2827

    Basic human body measurements for technological design — Statistical summaries of body measurements (ISO/TR 7250-2:2024, MOD)

    This document provides statistical summaries of body measurements measured according to ISO 7250-1, together with background database information for the working-age population in Malaysia, prepared in accordance with ISO 15535:2012. This document also describes the process of the measurement and preparation of statistical summaries

    UPC

    DOCUMENT

    PUBLIC COMMENT FORM

    Email: pc[at]jsm[dot]gov[dot]my

  • 15 MARCH 2026 - 15 APRIL 2026

    UNDER DEVELOPMENT

    15 MARCH 2026 - 15 APRIL 2026

    No.

    Title of DMS

    Scope

    Details

     

     NSC 12 - TRANSPORT

    1.

    DMS 2792 

    Passenger vehicle blind spot system for detection of motorcycle – System requirements and testing method

     

    This document specifies system requirements and test methods for blind spot detection technology to detect motorcycle in blind spot zone. This document applicable to M1 vehicle category and pick-up truck in accordance with MS 1822.


    This document addresses the technology for use on forward moving passenger vehicle on the road. It is intended to warn the driver of the subject vehicle against potential collisions with motorcycle in the blind spot zone and rear zone of the subject vehicle and moving on the same direction as the subject vehicle.

    UPC

    DOCUMENT

    PUBLIC COMMENT FORM

    Email: pc[at]jsm[dot]gov[dot]my

  • 15 MARCH 2026 - 15 MAY 2026

    UNDER DEVELOPMENT

    15 MARCH 2026 - 15 MAY 2026

    No.

    Title of DMS

    Scope

    Details

     

     NSC 12 - TRANSPORT

    1.

    DMS ISO 41011:2024

    Facility management — Vocabulary (ISO 41011:2024, IDT)

    This document defines terms used in facility management.

    UPC

    DOCUMENT

    PUBLIC COMMENT FORM

    Email: pc[at]jsm[dot]gov[dot]my

    2.

    DMS ISO 41015:2023 ⁠

    Facility management — Influencing organizational behaviours for improved facility outcomes (ISO 41015:2023, IDT)

    This document gives guidance on the ways in which a facility management (FM) organization can influence organizational behaviours to achieve improved facility outcomes, including how it can engage, empower and influence users, service providers and other interested parties with one another for improved outcomes and user experience while interfacing with the built environment.

    Consequently, and simultaneously, these behaviours can be harnessed to contribute to the achievement of the demand organization’s objectives and goals in an organizational sense, regardless of the type of organization or built environment involved. This is the fundamental link to the role of FM as defined in ISO 41001.

    This document is intended to build upon the requirements in ISO 41001, which adheres to the Plan-Do Check-Act methodology.

    This document is applicable to organizations both large and small.

    NOTE 1 For the purposes of this document, the term “organization” refers to the FM organization unless

    otherwise stated.

    UPC

    DOCUMENT

    PUBLIC COMMENT FORM

    Email: pc[at]jsm[dot]gov[dot]my

    3.

    DMS ISO 41017:2024

    Facility management — Guidance on emergency preparedness and management of an epidemic (ISO 41017:2024, IDT)

    This document provides general guidance to organizations on how to plan for, mitigate and/or manage the risks and impacts of an epidemic event to protect facility-related health, safety and well-being.

    This document is applicable to all organizations, fully or partially operating, resuming or new to operating

    UPC

    DOCUMENT

    PUBLIC COMMENT FORM

    Email: pc[at]jsm[dot]gov[dot]my

  • 1 APRIL 2026 - 30 MAY 2026

    UNDER DEVELOPMENT

    1 APRIL 2026 - 30 MAY 2026

    No.

    Title of DMS

    Scope

    Details

     

     NSC 11 - LOGISTICS

    1.

    DMS ISO 830:2024

    Freight containers - Vocabulary (ISO 8360:2024, IDT)

     

    This document defines terms and definitions related to containers.


    NOTE The different parts and components used in the construction of containers are specified in ISO 9897.

    UPC

    DOCUMENT

    PUBLIC COMMENT FORM

    Email: pc[at]jsm[dot]gov[dot]my

We use cookies

We use cookies on our website. Some of them are essential for the operation of the site, while others help us to improve this site and the user experience (tracking cookies). You can decide for yourself whether you want to allow cookies or not. Please note that if you reject them, you may not be able to use all the functionalities of the site.